§ 29.1395
Maximum intensities in overlapping beams of forward and rear position lights.
No position light intensity may exceed the applicable values in the following table, except as provided in § 29.1389(b)(3).
Overlaps
Maximum intensity
Area A (candles)
Area B (candles)
Green in dihedral angle L
10
1
Red in dihedral angle R
10
1
Green in dihedral angle A
5
1
Red in dihedral angle A
5
1
Rear white in dihedral angle L
5
1
Rear white in dihedral angle R
5
1
Where—
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and